EMF & RF
RF exposure surveys and EMF measurements
We measure radiofrequency fields around rooftop and in-building antennas against FCC limits, map the zones where access must be controlled, and measure 60 Hz magnetic fields near electrical equipment.
What we do
Measured, mapped and explained
- Rooftop RF surveysSpatially averaged measurements with calibrated broadband probes at walkways, mechanical areas and roof access points.
- Controlled-zone mappingDrawings showing where exposure can exceed general population limits, with recommendations for barriers and signage.
- RF awareness for building staffPlain-language guidance for supers, roofers and contractors who work near antennas.
- ELF magnetic field (EMF) surveys60 Hz measurements in apartments and offices near transformer vaults, electrical rooms and feeders.
- Tenant and buyer concernsIndependent measurements and a written explanation when occupants ask whether nearby equipment is safe.
Requirements
The limits we measure against
- RF limit
- FCC maximum permissible exposure (MPE) limits in 47 CFR §1.1310, which vary with frequency.
- Two tiers
- General population (uncontrolled) limits apply to anyone. Occupational (controlled) limits are five times higher and apply only to trained workers aware of the exposure.
- 60 Hz magnetic fields
- No US federal residential limit. ICNIRP 2010 reference levels: 2,000 mG (public) and 10,000 mG (occupational).
- Typical readings
- Background 60 Hz fields in most homes measure a few milligauss or less.
FCC maximum permissible exposure by frequency
Process
How an RF survey runs
Site review
We review the antenna inventory, roof layout and who has access, before going up.
Measurement
Spatially averaged readings over a 6-foot standing height on a grid across accessible areas.
Comparison
Each point is reported as a percentage of the general population and occupational MPE.
Report
Zone map, photos, readings and practical recommendations for access control and signage.
FAQ
Common questions
What does 3% of MPE mean?
The measured power density is 3% of the FCC limit for that frequency. Readings are summed across all frequencies present so the total can be compared with 100%.
Do the carriers have to shut antennas down for the survey?
No. We measure under normal operating conditions. Carriers may need to power down only when work must happen inside a controlled zone.
Are 5G antennas treated differently?
The same FCC rules apply. Millimeter-wave equipment above 1.5 GHz falls under the flat 1.0 and 5.0 mW/cm² limits shown in the chart.
Next step
Antennas on your roof?
Send the address and roof access details. We will quote a survey and a zone map.